9. Turn the bracket over and remove the two screws that attach the failed fan to the
bracket. Save these screws. You will reinstall them later. See letter “A” in
Figure 74.
10. Lift the fan from the bracket. See letter “B” in Figure 74.
Figure 74. Removing Fan from Fan Bracket (SR1630GPRX)
11. Install the replacement fan onto the bracket, using the two screws you removed in
Step 9.
12. Set the fan assembly into the system. Insert the rear edge first and push the
assembly slightly rearward to clear the hard disk drive brackets. Use caution to
make sure you do not pinch any cables.
13. Route the cable from the fan at the right around the right side of the assembly and
under the clip at the front of the fan bracket.