Viglen SX220 User Guide – MA-SX220-0A-01 User Guide®®C O M P U T E R S N E T W O R K S S O L U T I O N SMindsT h i n kG r
Viglen SX220 User Guide 9Chassis Back I/O Ports and Features The back panel provides connectors for the server board, slots for add-in cards, and th
Viglen SX220 User Guide 996. Insert the bootable diskette into drive A. 7. To extract the BIOS.EXE file to the diskette, change to the temporary d
Viglen SX220 User Guide 100 5. Reinstall the access cover and connect the power cord. 6. Insert the diskette holding the BIOS upgrade and recovery
Viglen SX220 User Guide 1017. The program will load the file and then ask if it should upload boot code. Press “N” to continue unless otherwise dir
Viglen SX220 User Guide 102 • Is compatible with ROM-DOS Ver. 6.22, MS-DOS Ver. 6.22 (and later versions), Windows 95 DOS, and Windows 98 DOS • Acc
Viglen SX220 User Guide 103specified CFG file and uses the entries in that file to probe the hardware and to select the proper SDRs to load into non-
Viglen SX220 User Guide 104 77.. IInntteell SSeerrvveerr CCoonnttrrooll Legal Information from software supplier An Intel ® product, when use
Viglen SX220 User Guide 105About Intel Server Control NOTE: This section describes the Intel Server Control (ISC) server-management package. Intr
Viglen SX220 User Guide 106 be used to validate and isolate problems in the server. The tests are controlled via a text-based console redirected to th
Viglen SX220 User Guide 107The next table shows the typical tasks that a system administrator might do. They include normal system administration, se
Viglen SX220 User Guide 108 of the software on the same server. It is also possible to install Platform Instrumentation on multiple servers and Consol
Viglen SX220 User Guide 10 Power Supply The power supply consists of the power supply bay and one power supply module. A second power supply module c
Viglen SX220 User Guide 109• Manage non-Intel-based systems via the Intelligent Chassis Management Bus (ICMB). • Remotely monitor server hardware
Viglen SX220 User Guide 110 Since DPC does not communicate with the server-resident operating system, it can be used to manage the server even if the
Viglen SX220 User Guide 111• Configuration registers The Client SSU stores configuration values in flash memory. These values take effect when you
Viglen SX220 User Guide 112 The DMI Explorer can be installed as a tool available from the ISC Console. Select “Install DMI Explorer” when you are ins
Viglen SX220 User Guide 113OpenView The HP OpenView Network Node Manager Console automatically detects servers running the ISC Platform Instrumentat
Viglen SX220 User Guide 114 Using the modem connection via the Direct Platform Control (DPC), you can: • Reset the remote server’s power. • Reboot
Viglen SX220 User Guide 115Setting Up an ICMB Connection An ICMB connection requires: • A managed server with an ICMB interface. • A server with
Viglen SX220 User Guide 116 further analyse the condition of the server. Pages can be configured for the following events: • Temperature Sensor out
Viglen SX220 User Guide 117Intel Server Control Console Main Screen The following figure shows the Intel Server Control Console. Figure 48: Intel
Viglen SX220 User Guide 118 Server Menu Options Discover You can discover multiple servers in a single step and add them to the server tree. Servers
Viglen SX220 User Guide 11of the system, some 2-post relay racks may not, causing the racks to fail. Only use relay racks that are specifically desig
Viglen SX220 User Guide 1194. Click OK. The ISC Console will test the specified server for all ISC-registered tools. If one or more of the tools is
Viglen SX220 User Guide 120 The Status Bar The status bar displays information about ISC Console operations, such as the number of servers found with
Viglen SX220 User Guide 12188.. SSoollvviinngg PPrroobblleemmss The first part of this chapter helps you identify and solve problems that might o
Viglen SX220 User Guide 122 Are all DIMMs installed correctly? Are all peripheral devices installed correctly? If the system has a hard disk
Viglen SX220 User Guide 123 If you are running the software from a CD-ROM disk, try a different disk to see if the problem occurs on all disks.
Viglen SX220 User Guide 124 5. Turn on the system. If the power LED does not light, see “Power Light Does Not Light” on page 125 6. If errors are
Viglen SX220 User Guide 125Try the solutions in the order given. If you cannot correct the problem, contact your service representative or authorise
Viglen SX220 User Guide 126 If the problem persists, the video monitor may be faulty or it may be the incorrect type. Contact your service represent
Viglen SX220 User Guide 127 Are all relevant switches and jumpers on the drive set correctly? Is the drive properly configured? Is the onboar
Viglen SX220 User Guide 128 Run the diagnostics. Problems with Application Software If you have problems with application software, do the follow
Viglen SX220 User Guide 12 33.. MMootthheerrbbooaarrdd SSppeecciiffiiccaattiioonn Server Board Features Table 2: Server Board Features Feature D
Viglen SX220 User Guide 12999.. TTeecchhnniiccaall RReeffeerreennccee Server Board Jumpers Figure 49: Server Board Jumpers Table 40: Configura
Viglen SX220 User Guide 130 nibble is represented by a red LED and each bit in the lower nibble is represented by a green LED. If both bits are set i
Viglen SX220 User Guide 131Table 41 : POST Codes (Continued) Diagnostic LED Decoder G=Green, R=Red, A=Amber Post Code MSB LSB Description 19h G
Viglen SX220 User Guide 132 Table 41 : POST Codes (Continued) Diagnostic LED Decoder G=Green, R=Red, A=Amber Post Code MSB LSB Description 39h G
Viglen SX220 User Guide 133Table 41 : POST Codes (Continued) Diagnostic LED Decoder G=Green, R=Red, A=Amber Post Code MSB LSB Description 9Bh A Of
Viglen SX220 User Guide 134 1100.. RReegguullaattoorryy && IInntteeggrraattiioonn IInnffoorrmmaattiioonn Product Regulatory Compliance
Viglen SX220 User Guide 135• AS/NZS 3548 (Class A) – Radiated & Conducted Emissions (Australia / New Zealand) • RRL (Class A) Radiated & C
Viglen SX220 User Guide 136 BSMI (Taiwan) The BSMI Certification number 3902I904 is silk screened on the component side of the server board; and the
Viglen SX220 User Guide 1371111.. EEqquuiippmmeenntt LLoogg && PPoowweerr CCoonnssuummppttiioonn Equipment Log Use the blank equipme
Viglen SX220 User Guide 138 Table 42: Equipment Log (continued) Item Manufacturer Name and Model Number Serial Number Date Installed
Viglen SX220 User Guide 13Server Board Connector and Component Locations Figure 4: Server Board components A – Speaker R – CPU 1 fan connector B
Viglen SX220 User Guide 139Current Usage NOTE: Both processors pull power from +5V. This may limit the number of drives and/or add-in cards you may
Viglen SX220 User Guide 140 Worksheet, Calculating DC Power Usage 1. List the current for each board and device in the appropriate voltage level colu
Viglen SX220 User Guide 141Worksheet, Total Combined Power Used by the System 1. From the previous worksheet, enter the total current for each colum
Viglen SX220 User Guide 142 1122.. AAppppeennddiixx Contacting Viglen Viglen Technical Support Tel: 020 8758 7050 Fax: 020 8758 7097 E-mail
Viglen SX220 User Guide 1431133.. NNootteess
Viglen SX220 User Guide 144
Viglen SX220 User Guide 145
Viglen SX220 User Guide 146 1144.. VViigglleenn,, EEMMCC aanndd tthhee ‘‘CCEE’’ mmaarrkk CE Marking As we begin the 21st century, European st
Viglen SX220 User Guide 1471155.. CCooppyyrriigghhttss aanndd TTrraaddeemmaarrkkss Please note The material in this manual is subject to chang
Viglen SX220 User Guide 148 1166.. SSuuggggeessttiioonnss Viglen is interested in continuing to improve the quality and information provided in th
Viglen SX220 User Guide 14 Back Panel Connectors Figure 5: Back Plane Connectors A – USB 1 connector G – NIC 1 RJ-45 connector B – Video connecto
Viglen SX220 User Guide 1495. How do you rate the Viglen Technical support and Service Departments?
Viglen SX220 User Guide 15Processor The SCB2 motherboard accommodates one or two Intel Pentium III processors with 512k cache in the FC-PGA2 package
Viglen SX220 User Guide 16 Video The SCB2 motherboard uses an ATI RAGE XL PCI graphics accelerator with 8 MB of video SDRAM that supports all standar
Viglen SX220 User Guide 17Network Controller NOTE: To ensure EMC product regulation compliance, the system must be used with a shielded LAN cable.
Viglen SX220 User Guide 18 • Adaptive Load Balancing (ALB) - creates a team of 2 - 8 adapters to increase transmission throughput. Also includes AFT.
Viglen SX220 User Guide 1CCoonntteennttss 1. Overview 5 Introduction 5 2. Chassis Specifications 6 Chassis Specification
Viglen SX220 User Guide 19Mixed Adapter Teaming AFT supports up to eight server adapters per team, in any mix. Adaptive Load Balancing Adaptive Lo
Viglen SX220 User Guide 20 The 8 pins of the RJ45 connector can be configured to match either of two pin-out standards used by serial port concentrato
Viglen SX220 User Guide 21NOTE: The RJ45-to-DB9 adapter should match the configuration of the serial device used. One of two pin-out configurations a
Viglen SX220 User Guide 22 be configured through ISC to respond to an intrusion a number of ways, including powering down or locking the keyboard. So
Viglen SX220 User Guide 23• May enter the user password to enter BIOS Setup or the SSU. However, you will not be able to change many of the options.
Viglen SX220 User Guide 24 The server can boot and run the operating system, but mouse and keyboard input is not accepted until the user password is
Viglen SX220 User Guide 25Password menu of the User Password Option menu found in the Security Subsystem Group. To clear the password if you cannot
Viglen SX220 User Guide 26 44.. AAsssseemmbblliinngg tthhee SSyysstteemm This chapter will give a step-by-step guide of installing the server boa
Viglen SX220 User Guide 27Warnings and Cautions! These warnings and cautions apply whenever you remove the access cover to access components inside
Viglen SX220 User Guide 28 Installing the Server Board Installing the server board consists of the following steps: • Removing the cover, Riser car
Viglen SX220 User Guide 2 Installing the Fan Assembly 34 Installing the Power Cord and Strain Relief Strap 35 Adding Components to the Se
Viglen SX220 User Guide 292. Lift straight up and remove it from the chassis. 3. Insert your finger in the plastic loop on riser card (B). 4. Pu
Viglen SX220 User Guide 30 Figure 10: Removing the Fan Assembly Installing the Server Board 1. Ensure that the Mylar insulator sheet is seated se
Viglen SX220 User Guide 31 Figure 11: Attaching the Server Board
Viglen SX220 User Guide 32 Routing Cables Figure 12: Routing Cables 1. Route the backplane power cable (A) from the power supply to the backplane
Viglen SX220 User Guide 335. Connect the end of the flex circuit cable (C) labeled to the floppy/front panel/IDE connector on the server board. Rout
Viglen SX220 User Guide 34 Installing the Fan Assembly CAUTION! When installing the fan assembly, avoid pinching cables routed in the area. 1. Ens
Viglen SX220 User Guide 35 Figure 14: System Fan Connectors 6. Connect the USB cable to the 10-pin USB connector on the server board (Figure 4, Po
Viglen SX220 User Guide 36 Adding Components to the Server Board After installing the server board, you must add the desired number of processors and
Viglen SX220 User Guide 37 Figure 17: Inserting the Processor 7. Following the instructions packaged with the applicator, apply thermal grease to t
Viglen SX220 User Guide 38 Figure 18: Installing the Heatsink A. Heat sink retention clip B. Heat sink C. Socket and processor CAUTION! Use car
Viglen SX220 User Guide 3Software Updates 96 Software Update Package 96 Individual Updates 98 Upgrading the BIOS 99 Recove
Viglen SX220 User Guide 39 Figure 19: Locking Heatsink Lever 12. Install the fan on the processor heat sink making sure that it is seated flat on th
Viglen SX220 User Guide 40 Install the Processor Terminator If you are installing only one processor, you must install a terminator in the secondary
Viglen SX220 User Guide 41 Figure 22: Installing DIMMs Installing Peripherals Peripherals and add-in cards are not included in your system and must
Viglen SX220 User Guide 42 3. Firmly push the PCI card connector into the riser card slot until it is fully seated. 4. Close the retainer clip (A).
Viglen SX220 User Guide 43 Figure 24: Installing a Riser Card Installing a Hard Drive The server can support up to seven hot swappable hard drives
Viglen SX220 User Guide 44 Figure 25: Hard Drive Carrier 5. Remove the hard drive from its wrapper and place it on an anti-static surface. 6. Set
Viglen SX220 User Guide 4511. Reinstall a carrier/air baffle in any bays where you are not installing a carrier/drive. Installing a CD-ROM Drive/FDD
Viglen SX220 User Guide 46 NOTE: Using the legacy IDE connector on the SCB2 server board to support an IDE peripheral device in the SX220 server is no
Viglen SX220 User Guide 47CAUTION! Carefully route cables to minimise airflow blockage and cooling problems. Suggested Tape Drive Cabling A periph
Viglen SX220 User Guide 48 Figure 30: Onboard SCSI Connector Connecting to a SCSI Controller on a Full-height PCI Card 1. Obtain a SCSI cable with
Viglen SX220 User Guide 4 Current Usage 139 Calculating Power Consumption 139 Worksheet, Calculating DC Power Usage 140 Workshee
Viglen SX220 User Guide 49Connecting to a SCSI Controller on a Low Profile PCI Card 1. Obtain a SCSI cable with an unfolded length of 26-inches. 2
Viglen SX220 User Guide 50 Installing the Bezel Place the bezel between the chassis handles and push it toward the front of the chassis until it snap
Viglen SX220 User Guide 5155.. IInnssttaalllliinngg tthhee SSyysstteemm iinn aa RRaacckk CAUTION! ANCHOR THE EQUIPMENT RACK: The equipment r
Viglen SX220 User Guide 52 Removing the Rails 1. Fully extend a rail assembly (Figure 35). The finger tab (D) for the extension lock is revealed. 2
Viglen SX220 User Guide 53 Figure 36: Attaching the Rails A. Inside rail B. #6-32 x 3/16-inch screw C. Attachment hole D. Attachment tab E. Attach
Viglen SX220 User Guide 54 Attach a Rail Assembly to a Front Bracket 1. Position a rail assembly (middle and outer rails) with its black plastic end
Viglen SX220 User Guide 55A. Front bracket B. Outer rail C. Screw hole D. Threaded hole E. Not Shown F. Access hole G. #6-32 x 3/16-inch screw Atta
Viglen SX220 User Guide 56 Figure 40: Rails Fully Extended CAUTION! Lifting and placing the chassis in the rails is a two-person job. If needed, u
Viglen SX220 User Guide 5766.. CCoonnffiigguurraattiioonn SSooffttwwaarree aanndd UUttiilliittyy This chapter describes the Power-On Self-Tes
Viglen SX220 User Guide 58 To remove the splash screen. <ESC> Power-On Self-Test (POST) Each time you turn on the system, POST starts running
Viglen SX220 User Guide 511.. OOvveerrvviieeww Introduction This manual describes the Viglen SX220 system and the SCB2 motherboard. The motherbo
Viglen SX220 User Guide 59Using BIOS Setup This section describes the BIOS Setup options. Use Setup to change the server configuration defaults. Y
Viglen SX220 User Guide 60 Main Menu You can make the following selections on the Main Menu itself. Use the submenus for other selections. Table 8:
Viglen SX220 User Guide 61Processor Retest Disabled Enabled Select yes for the BIOS to clear historical processor status and retest all processors on
Viglen SX220 User Guide 62 Disabled present on a PCI add-in card installed in the slot In a 2U chassis, options for additional PCI slots PCI bus C wil
Viglen SX220 User Guide 63Peripheral Configuration Submenu Table 18: Peripheral Configuration Submenu Features Feature Choices Description Serial Po
Viglen SX220 User Guide 64 Wake on LAN Disabled Enabled Legacy wake only: Determines the action of the system when a LAN wake up event occurs. Wake o
Viglen SX220 User Guide 65Server Menu Table 22: Server Menu Features Feature Choices Description System Management Press <Enter> Enters Sub
Viglen SX220 User Guide 66 COM2 2F8 IRQ3 management features. Make sure these values are identical to those of Serial Port A and B in the Peripheral
Viglen SX220 User Guide 67Table 27: Boot Device Priority Submenu Features Boot Priority Device Description 1st Boot Device Removable Attempts to
Viglen SX220 User Guide 68 Exit Menu You can make the following selections on the Exit Menu. Select an option using the up or down arrow keys. Press
Viglen SX220 User Guide 6 22.. CChhaassssiiss SSppeecciiffiiccaattiioonn The SX220 system consists of the following major components: • The chas
Viglen SX220 User Guide 69When to Run the Adaptec SCSISelect Utility Use the SCSISelect utility to: • Change default values • Check and/or chang
Viglen SX220 User Guide 70 SCSI Disk Utilities Press <Enter> to view the SCSI Disk Utilities Menu. This menu allows you to format hard disks
Viglen SX220 User Guide 71DPC console runs on a client workstation. It communicates with a server by: • Accessing the server management capabiliti
Viglen SX220 User Guide 72 Console go directly to the server, and the DPC Console displays the text that you would normally see on the server console.
Viglen SX220 User Guide 73What You Need to Do You can run the SSU directly from the SCB2 Server Software Kit CD-ROM by booting the server system to
Viglen SX220 User Guide 74 a. After creating set of three SSU diskettes from the CD: Insert the first SSU diskette in drive A, and press the reset b
Viglen SX220 User Guide 75• Colour - this button lets you change the default colors associated with different items on the screen with predefined co
Viglen SX220 User Guide 76 OR • Highlight the task name, and click on OK. OR • Use the tab and arrow keys to highlight the desired button, and pr
Viglen SX220 User Guide 77Admin Password Button The ‘Admin Password’ button allows the user to set or change the administrative password used by bot
Viglen SX220 User Guide 78 • Lockout Timer—Set an interval that, if no activity takes place, it will drop the server into secure mode. • Secure Boo
Viglen SX220 User Guide 7Physical Specifications The SX220 chassis is designed as a 2U 19” Rackmount unit. The server will be supplied complete wi
Viglen SX220 User Guide 79SEL The SEL menu has the following options: • Properties: Displays information about the SEL. These fields are display
Viglen SX220 User Guide 80 View The View menu has the following options: • FRU Info: Displays information about the FRU. These fields are display
Viglen SX220 User Guide 81SDR Manager Add-in The Sensor Data Record (SDR) Manager Add-in component allows users to view sensor data records stored i
Viglen SX220 User Guide 82 • Verify firmware code currently loaded versus an external hex file. • Update the BIOS from .bio or .uif files. The Sys
Viglen SX220 User Guide 83• PCI records in non-volatile storage • Non-volatile emergency management port (EMP), platform event paging (PEP), and P
Viglen SX220 User Guide 84 Recovery Agent If the BMC firmware remote update fails, the server will reboot into the service partition and the recovery
Viglen SX220 User Guide 85Platform Event Manager Add-in The Platform Event Manager (PEM) provides an interface for configuring Platform Event Paging
Viglen SX220 User Guide 86 Platform Event Paging Dialog This dialog allows you to configure the Platform Event Paging features. (See Figure 44) F
Viglen SX220 User Guide 87Help Topics The Help Topics menu has the following options: • Help Topics: Displays help information. Enable PEP Chec
Viglen SX220 User Guide 88 Figure 45: BMC LAN-Configuration Dialog File The File menu has the following options: • Save: Allows you to save th
Viglen SX220 User Guide 8 Front Panel Controls and Indicators Figure 2: Front Panel Controls and Indicators A – NIC 1 activity LED I – Power/sleep
Viglen SX220 User Guide 89Help Topics Menu The Help Topics menu has the following options: • Help Topics: Displays help information. Enable LAN
Viglen SX220 User Guide 90 Gateway IP Address Enter the Logical or Internet Address of the router. The Gateway IP Address will only be saved when D
Viglen SX220 User Guide 91 Figure 46 : Platform Event Action Dialog File Menu The File menu has the following options: • Save: Allows you to sa
Viglen SX220 User Guide 92 Buttons • >>: Moves all the events from the enabled listbox to the disabled listbox. • >: Moves the selected
Viglen SX220 User Guide 93• Save: Allows you to save the configuration immediately. • Close: Allows you to close the Emergency Management Port d
Viglen SX220 User Guide 94 Modem Init String The Modem Init String string is transmitted every time the EMP initialises. The length of the paging st
Viglen SX220 User Guide 95Platform Event Paging With Platform Event Paging (PEP), your server can automatically dial up a paging service and page yo
Viglen SX220 User Guide 96 Software Updates Your system comes with preinstalled system BIOS and BMC firmware. When necessary, updates will be availa
Viglen SX220 User Guide 972. Print, review, and follow the instruction.rtf file (it supercedes any other instructions) 3. Label three blank floppy
Viglen SX220 User Guide 98 3. Disk 3 – SCB2 FRU/SDR update—Prompts you to choose the chassis type. You can choose to update the chassis information;