Intel
®
Entry Server Chassis SC5299-E TPS Power Sub-system
Revision 3.1
Intel order number D37594-005
91
2.5.7.6 AC Line Fuse
The power supply has one line fused in the single line fuse on the line (Hot) wire of the AC
input. The line fusing is acceptable for all safety agency requirements. The input fuse is a slow
blow type. AC in-rush current does not cause the AC line fuse to blow under any conditions. All
protection circuits in the power supply do not cause the AC fuse to blow unless a component in
the power supply has failed. This includes DC output load short conditions.
2.5.7.7 AC In-rush
AC line in-rush current does not exceed 50A peak, cold start at 20 degrees C, and no
component is damages at hot start for up to one-quarter of the AC cycle, after which, the input
current is no more than the specified maximum input current listed in