Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN TPS
Appendix B: Integrated BMC Sensor Tables
Revision 2.0 47
Intel order number G17455-004
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Reading
Type
Event Offset Triggers Contrib. To
System Status
Assert/De-
assert
Readable
Value/Off
sets
Event
Data
Rearm Stand-by
Processor DIMM
Thermal Trip
(Mem P1 Thrm Trip)
C0h All
Temperature
01h
Digital Discrete
03h
01 – State Asserted Fatal
As and
De
Trig
Offset
M X
Baseboard +12V
(BB +12.0V)
D0h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A
Baseboard +5V
(BB +5.0V)
D1h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A
Baseboard +3.3V
(BB +3.3V)
D2h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A
Baseboard +5V
Stand-by
(BB +5.0V STBY)
D3h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
Baseboard +3.3V
Auxiliary
(BB +3.3V AUX)
D4h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A X
Baseboard +1.2V
Processor Vccp
(BB P1 Vccp)
D6h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A
Baseboard +1.5V
VDDQ
(BB +1.5V P1 MEM)
D8h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and
De
Analog R, T A