42 Intel
®
Server System SR1630GPRX/SR1630HGPRX Service Guide
7. Orient the processor with the socket so the processor cutouts match the socket
notches. See letter “A” in Figure 26.
8. Set the processor into place as shown by letter “B” in Figure 26.
Figure 26. Installing the Processor
Note: Make sure the alignment triangle mark and the alignment triangle cutout align correctly.
9. Remove the protective socket cover. See Figure 27.
Figure 27. Removing the Protective Socket Cover
Note: Retain the protective socket cover for use when removing a processor that will not be
replaced.